___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 20. 8. 2025 21:28:42 Faults found. U1202 ___________________ ___________________________ 'Clear fault codes' command sent ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 20. 8. 2025 21:55:52 No faults reported by the unit. ___________________ ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 22. 8. 2025 18:07:17 Faults found. U0111 ___________________ Error code: U0111 Lost Communication With Battery Energy Control Module Last test completed positively Error present Failure warning lamp 'ON': Not requested Error code: U0111 Lost Communication With Battery Energy Control Module Last test completed positively Error present Failure warning lamp 'ON': Not requested ___________________________ 'Clear fault codes' command sent ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 25. 8. 2025 18:49:23 No faults reported by the unit. ___________________ ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 25. 8. 2025 19:42:45 No faults reported by the unit. ___________________ ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 28. 8. 2025 20:16:48 No faults reported by the unit. ___________________ ___________________________ Reading faults for: On-Board Charging Module ___________________ Faults reported: 28. 8. 2025 20:38:28 Faults found. U1202 U0111 ___________________ ___________________________ 'Clear fault codes' command sent Odometer at last rewrite: 25,50 km Odometer at last rewrite: 25,50 km Number of rewrites: 1 Functioning time (eeprom): 9358 min Time since Key-On (eeprom): 8895 sec ECU Time Stamps (RAM): 13 min ECU Time Stamps From Key On (RAM): 795 sec Key On Counter (EEPROM): 154 ECU Time first DTC detection (EEPROM): 0 min ECU Time Stamps from KeyOn first DTC detection (EEPROM): 0 sec Key-On counter alignment: 0 OBCM Status AC Present: AC Not OK AC Line Low: Not valid AC Line High: Not valid Battery Not Detected: No Battery Voltage Under Min: Yes Battery Voltage Over Max: Yes BPCM HV Battery Contractor Open: No HV OC: No HV OV: No NTC1 OT: No NTC2 OT: No NTC3 OT: No NTC4 OT: No J1772 S2 Close: Open J1772 State: Connection Not Ready J1772 S2 Status: Open EVSE Pilot State: CP DET Prox State: Prox IN OBC Charge Time, sec: 0 sec OBC Charge Time, hours: 11803 H OBC Idle Time, sec: 21 sec OBC Idle Time, hours: 225 H OBCM Mode: Idle OBCM Charger Ready: On OBCM WU Status: On Charge Enable Status: Disabled EVCU Shutdown Command: EVCU Operational EVCU Enable Charge Command: Disabled EVCU OBC Mode Request: Idle Generic Fail Sts: No Functional Fail Present Charge Fail Statue: Fault Detected OBC Control Method: Current Close Charge Contractor: Open Charge Contractor State: Not defined Charge Mode: Charge Mode EVCU Wake Up Input: Wakeup is Faulted BPCM Wake Up Input: Wakeup is Faulted OBCM - HV Over Voltage Protect: No OBCM - LV Aux Over Voltage Protect: No OBCM - LV Aux Under Voltage Protect: No OBCM - LLC Over Voltage Protect: No OBCM - LLC Under Voltage Protect: No OBCM - PFC Over Voltage Protect: No OBCM - PFC Under Voltage Protect: No OBCM - Battery 12V Under Voltage Protect: No OBCM - Battery 12V Over Voltage Protect: No OBCM - AC Under Voltage Protect: No OBCM - AC Over Voltage Protect: No OBCM - AC Over Current Protect: No OBCM - HV Voltage Over MaxCal Protect: No OBCM - HV Over Current Protect: No OBCM - Power Stage Over Voltage Protect: No OBCM - Internal Memory Fault: No OBCM - Over Temperature Protect: No OBCM - HCP Loss of Communication Protect: No OBCM - Loss BPCM Communication Protect: No OBCM - CAN Bus Off: No OBCM - Pilot Duty Fault: No OBCM - Prox Range Too Low: No OBCM - Prox Range Too High: No OBCM - HV Voltage Under MinCal Protect: No OBCM - SPI Communication Fault: No OBCM - Pilot Short To Battery: No OBCM - WakeUp Output Stuck Low: No OBCM - WakeUp Output Stuck High: No OBCM - ORC Loss of Communication Protect: No OBCM - HV Battery Not Contact: No OBCM - Loss Communication Protect: No OBCM - Receive HV Battery Contact Open From BPCM: No OBCM - Secondary Aux Over Voltage Protect: No OBCM - Secondary Aux Under Voltage Protect: No OBCM - Primary Aux Over Voltage Protect: No OBCM - Primary Aux Under Voltage Protect: No OBCM - Stuck Shutdown: No OBCM - Cycle Shutdown: No OBCM - HV Under Voltage Protect: No OBCM - Vehicle Impact: Yes OBCM - ARC/CRC Fault: No OBCM - AC Contact Welded Fault: No Loss ECM/PCM Communications Protect: No OBCM - Aux Into Pilot Switch Low Fault: No OBCM - Aux Into Pilot Switch High Fault: No OBCM - Pilot Range Fault: No OBCM - Prox Range Fault: No OBCM - Pilot Open Fault: No OBCM - Prox Open Fault: No OBCM - Internal S2 Switch Low Fault: No OBCM - Internal S2 Switch High Fault: No BPCM Wake Up Input Stuck Low Fault: No BPCM Wake Up Input Stuck High Fault: No HCP Wake Up Input Stuck Low Fault: No HCP Wake Up Input Stuck High Fault: No OBCM - Wake Up Output Open Fault: No Module A Primary - AC Under Voltage Protect: No Module A Primary - PFC Power Limit: No Module A Primary - PFC Enable States: No Module A Primary - LLC Enable States: No Module A Primary - PFC Under Voltage Protect: No Module A Primary - PFC Over Voltage Protect: No Module A Primary - Over Temperature Protect: No Module A Primary - Hot Warning: No Module A Primary - AC Present: No Module A Primary - PFC Over Temperature Protect: No Module A Primary - LLC Over Temperature Protect: Yes Module A Primary - PFC Hot Warning: No Module A Primary - LLC Hot Warning: No Module A Primary - AC Over Voltage Protect: No Module A Primary - Relay Enable States: No Module A Primary - Aux Over Voltage Protect: No Module A Primary - Aux Under Voltage Protect: No Module A Primary - Secondary Micro Enable Command: No Module A Primary - AC Vin Lost: No Module A Primary - Loss Communication Protect: No Module A Primary - Standby Mode: No Module A Primary - Operate Mode: No Module A Primary - Shutdown Mode: Yes Module A Secondary - Aux Enable States: No Module A Secondary - HV Enable States: No Module A Secondary - LLC Under Voltage Protect: No Module A Secondary - LLC Over Voltage Protect: No Module A Secondary - HV Over Voltage Protect: No Module A Secondary - HV Over Current Protect: Yes Module A Secondary - Over Temperature Protect: No Module A Secondary - Hot Warning: No Module A Secondary - HV Over Temperature Protect: No Module A Secondary - Ambient Over Temperature Protect: No Module A Secondary - HV Hot Warning: No Module A Secondary - Ambient Hot Warning: No Module A Secondary - Aux Over Voltage Protect: No Module A Secondary - Aux Under Voltage Protect: No Module A Secondary - Loss Primary Communication Protect: No Module A Secondary - LV Micro Enable Command: No Module A Secondary - Loss LV Communication Protect: Yes Module A Secondary - Primary Turn On States: No Module A Secondary - Primary Shutdown States: No Module A Secondary - HV Under Voltage Protect: No Module A Secondary - Standby Mode: No Module A Secondary - Operate Mode: No Module A Secondary - Shutdown Mode: No Module B Primary - AC Under Voltage Protect: No Module B Primary - PFC Power Limit: No Module B Primary - PFC Enable States: No Module B Primary - LLC Enable States: No Module B Primary - PFC Under Voltage Protect: No Module B Primary - PFC Over Voltage Protect: No Module B Primary - Over Temperature Protect: No Module B Primary - Hot Warning: No Module B Primary - AC Present: No Module B Primary - PFC Over Temperature Protect: No Module B Primary - LLC Over Temperature Protect: No Module B Primary - PFC Hot Warning: No Module B Primary - LLC Hot Warning: No Module B Primary - AC Over Voltage Protect: Yes Module B Primary - Relay Enable States: No Module B Primary - Aux Over Voltage Protect: No Module B Primary - Aux Under Voltage Protect: No Module B Primary - Secondary Micro Enable Command: No Module B Primary - AC Vin Lost: No Module B Primary - Loss Communication Protect: No Module B Primary - Standby Mode: No Module B Primary - Operate Mode: No Module B Primary - Shutdown Mode: No Module B Secondary - Aux Enable States: No Module B Secondary - HV Enable States: No Module B Secondary - LLC Under Voltage Protect: No Module B Secondary - LLC Over Voltage Protect: Yes Module B Secondary - HV Over Voltage Protect: No Module B Secondary - HV Over Current Protect: No Module B Secondary - Over Temperature Protect: No Module B Secondary - Hot Warning: No Module B Secondary - HV Over Temperature Protect: No Module B Secondary - Ambient Over Temperature Protect: No Module B Secondary - HV Hot Warning: No Module B Secondary - Ambient Hot Warning: No Module B Secondary - Aux Over Voltage Protect: No Module B Secondary - Aux Under Voltage Protect: No Module B Secondary - Loss Primary Communication Protect: Yes Module B Secondary - LV Micro Enable Command: No Module B Secondary - Loss LV Communication Protect: No Module B Secondary - Primary Turn On States: No Module B Secondary - Primary Shutdown States: No Module B Secondary - HV Under Voltage Protect: Yes Module B Secondary - Standby Mode: No Module B Secondary - Operate Mode: Yes Module B Secondary - Shutdown Mode: No OBCM Plant Mode: Normal Mode (Application) Charging Test Status: Test Passed Charging Test Failure Code: Not Programmed J1772 Pilot Circuit Status: CP DET J1772 Proximity Circuit Status: Prox IN J1772 Encoded State: Connection Ready No Vent ______________________